Please use this identifier to cite or link to this item: https://dspace.sduaher.ac.in/jspui/handle/123456789/8337
Full metadata record
DC FieldValueLanguage
dc.contributor.authorMinni Meka, Raveesha A, Jagmohan S V, Niveditha S.-
dc.date.accessioned2023-10-31T09:56:30Z-
dc.date.available2023-10-31T09:56:30Z-
dc.date.issued2020-01-
dc.identifier.urihttp://172.16.4.202:8080/xmlui/handle/123456789/8337-
dc.description.abstractThe risk of developing tuberculosis (TB) is found to be 20 times greater in people living with Human immunodeficiency virus (HIV) than among those without HIV infection. Objective: To evaluate the accuracy of Gene Xpert for detection of MTB in HIV patient suspected for tuberculosis and comparing with conventional acid fast smear examination. Methodology: The study was conducted in Medicine OPD and Pulmonology OPD of R L Jalappa Hospital, Tamaka, and Kolar. ART center and RNTCP center, SNR Government Hospital. Study Design: Cross sectional study. Study Period: 1 year. Sample Size: 225 subjects Results: Smear microscopy has Sensitivity 45.03%, Specificity 100%, NPV 11.76% and PPV 100% for pulmonary specimens, Smear microscopy has Sensitivity 16.67%, Specificity 100%, NPV 44.44% and PPV 100% for extra pulmonary specimens. Overall Smear microscopy has Sensitivity 43.35%, Specificity 100%, NPV 16.06% and PPV 100%.Gene Xpert has Sensitivity 87.43%, Specificity 92.86%, NPV 35.14% and PPV 99.40% for pulmonary specimens, Gene Xpert has Sensitivity 83.33%, Specificity 100%, NPV 80% and PPV 100% for extra pulmonary specimens. Overall Smear microscopy has Sensitivity 87.19%, Specificity 95.45%, NPV 44.68% and PPV 99.44%. Conclusion: The Gene Xpert MTB is a rapid, sensitive and a reliable diagnostic test for TB than smear microscopy in both pulmonary as well as extra pulmonary TB.The results of this study indicate that the implementation of the Gene Xpert (MTB/RIF) assay could dramatically improve the rapid diagnosis of extra pulmonary tuberculosis as well in HIV infected patients.en_US
dc.language.isoenen_US
dc.subjectSmear Microscopy, Xpert MTB, HIV, Pulmonary Tuberculosis, Extra Pulmonary Tuberculosis.en_US
dc.titleDiagnostic Accuracy of Gene Xpert vs Acid Fast Smear in HIV Patients Suspected for Tuberculosisen_US
dc.typeArticleen_US
Appears in Collections:Medicine

Files in This Item:
File Description SizeFormat 
Diagnostic Accuracy of Gene Xpert vs Acid Fast Smear in HIV Patients.pdf373.3 kBAdobe PDFView/Open


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.